Cisco 交换机端口故障分析(一)
Cisco 交换机端口故障分析(一) 两台Catalyst 6000 之间互联的GE2/1出现了errdisable故障,what's up告警,链路中断。 查看log记录: Sep 4 19:18:50 UTC: %PM-SP-4-ERR_DISABLE: link-flap error detected on Gi2/1, putting Gi2/1 in err-disable state Sep 4 19:19:09 UTC: %OSPF-5-ADJCHG: Process 108, Nbr **** on Vlan12 from FULL to DOWN, Neighbor Down: Dead timer expired Sep 5 00:03:34 UTC: %SYS-5-CONFIG_I: Configured from console by gcc&et on vty0 Sep 5 00:07:10 UTC: %SYS-5-CONFIG_I: Configured from console by gcc&et on vty0 Sep 5 00:08:13 UTC: %PM-SP-4-ERR_RECOVER: Attempting to recover from link-flap err-disable state on Gi2/1 Sep 5 00:08:58 UTC: %OSPF-5-ADJCHG: Process 108, Nbr **** on Vlan12 from LOADING to FULL, Loading Done Sep 5 05:14:07 UTC: %OSPF-5-ADJCHG: Process 108, Nbr **** on Vlan12 from LOADING to FULL, Loading Done Sep 5 06:06:17 UTC: %OSPF-5-ADJCHG: Process 108, Nbr **** on Vlan12 from FULL to DOWN, Neighbor Down: Dead timer expired Sep 5 06:06:47 UTC: %OSPF-5-ADJCHG: Process 108, Nbr **** on Vlan12 from LOADING to FULL, Loading Done Sep 5 06:14:34 UTC: %OSPF-5-ADJCHG: Process 108, Nbr **** on Vlan12 from FULL to DOWN, Neighbor Down: Dead timer expired Sep 5 06:14:37 UTC: %OSPF-5-ADJCHG: Process 108, Nbr **** on Vlan12 from LOADING to FULL, Loading Done Sep 5 06:26:58 UTC: %OSPF-5-ADJCHG: Process 108, Nbr **** on Vlan12 from LOADING to FULL, Loading Done 注: 由于为真实的网络环境,为了不必要的安全隐患,以****代替IP地址,请各位见谅! 故障处理: 进入configure终端模式,具体如下: SW1>en Password: SW1#conf t Enter configuration commands, one per line. End with CNTL/Z. SW1(config)#err? errdisable SW1#errdi SW1#errdisable ? detect Error disable detection recovery Error disable recovery SW1(config)#errdisable re SW1(config)#errdisable recovery ? cause Enable error disable recovery for application interval Error disable recovery timer value SW1(config)#errdisable recovery cau SW1(config)#errdisable recovery cause ? all Enable timer to recover from all causes bpduguard Enable timer to recover from BPDU Guard error disable state channel-misconfig Enable timer to recover from channel misconfig disable state dtp-flap Enable timer to recover from dtp-flap error disable state l2ptguard Enable timer to recover from l2protocol-tunnel error disable state link-flap Enable timer to recover from link-flap error disable state pagp-flap Enable timer to recover from pagp-flap error disable state psecure-violation Enable timer to recover from psecure violation disable state udld Enable timer to recover from udld error disable state SW1(config)#errdisable recovery cause all ? SW1(config)#errdisable recovery cause all 执行此命令后 不久端口就显示connected状态 What's up 告警消失。 Log Buffer (4096 bytes): : Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from LOADING to FULL, Loading Done Jul 2 13:04:47.533 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from FULL to DOWN, Neighbor Down: Interface down or detached Jul 2 13:05:30.128 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from LOADING to FULL, Loading Done Jul 2 13:06:50.126 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from INIT to DOWN, Neighbor Down: Interface down or detached Jul 2 13:07:40.137 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from LOADING to FULL, Loading Done Jul 2 13:17:49.948 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from FULL to DOWN, Neighbor Down: Interface down or detached Jul 2 13:18:33.135 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from LOADING to FULL, Loading Done Jul 2 13:18:46.175 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from FULL to DOWN, Neighbor Down: Interface down or detached Jul 2 13:19:29.134 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from LOADING to FULL, Loading Done Jul 2 13:21:13.507 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from FULL to DOWN, Neighbor Down: Interface down or detached Jul 2 13:21:56.106 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from LOADING to FULL, Loading Done Jul 2 13:30:22.296 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from FULL to DOWN, Neighbor Down: Interface down or detached Jul 2 13:31:05.091 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from LOADING to FULL, Loading Done Jul 2 13:31:56.185 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from FULL to DOWN, Neighbor Down: Interface down or detached Jul 2 13:32:31.120 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from 2WAY to DOWN, Neighbor Down: Interface down or detached Jul 2 13:33:14.083 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from LOADING to FULL, Loading Done Jul 2 13:34:09.958 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from FULL to DOWN, Neighbor Down: Interface down or detached Jul 2 13:34:52.113 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from LOADING to FULL, Loading Done Jul 2 13:37:54.624 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from FULL to DOWN, Neighbor Down: Interface down or detached Jul 2 13:38:07.063 BJT: %PM-4-ERR_DISABLE: link-flap error detected on Gi1/1, putting Gi1/1 in err-disable state Jul 2 13:38:35.347 BJT: %PM-4-ERR_RECOVER: Attempting to recover from link-flap err-disable state on Gi1/1 Jul 2 13:39:18.085 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from LOADING to FULL, Loading Done Jul 2 13:39:55.432 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from FULL to DOWN, Neighbor Down: Interface down or detached Jul 2 13:40:13.488 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from 2WAY to DOWN, Neighbor Down: Interface down or detached Jul 2 13:40:56.075 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from LOADING to FULL, Loading Done Jul 2 13:44:03.098 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from FULL to DOWN, Neighbor Down: Interface down or detached Jul 2 13:44:42.121 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from 2WAY to DOWN, Neighbor Down: Interface down or detached Jul 2 13:45:06.340 BJT: %PM-4-ERR_DISABLE: link-flap error detected on Gi1/1, putting Gi1/1 in err-disable state Jul 2 13:45:32.083 BJT: %PM-4-ERR_RECOVER: Attempting to recover from link-flap err-disable state on Gi1/1 Jul 2 13:46:26.066 BJT: %OSPF-5-ADJCHG: Process 100, Nbr 172.19.253.2 on GigabitEthernet1/1 from LOADING to FULL, Loading Done // no file verify auto errdisable recovery cause udld errdisable recovery cause bpduguard errdisable recovery cause security-violation errdisable recovery cause channel-misconfig errdisable recovery cause pagp-flap errdisable recovery cause dtp-flap errdisable recovery cause link-flap errdisable recovery cause gbic-invalid errdisable recovery cause l2ptguard errdisable recovery cause psecure-violation errdisable recovery cause dhcp-rate-limit errdisable recovery cause unicast-flood errdisable recovery cause vmps errdisable recovery cause storm-control errdisable recovery cause arp-inspection errdisable recovery interval 30 spanning-tree mode pvst spanning-tree extend system-id power redundancy-mode redundant ! ! ! ********************************** 防止err-disable,使用以下命令:errdisable recovery cause udld errdisable recovery cause bpduguard errdisable recovery cause security-violation errdisable recovery cause channel-misconfig errdisable recovery cause pagp-flap errdisable recovery cause dtp-flap errdisable recovery cause link-flap errdisable recovery cause psecure-violation errdisable recovery cause vmps errdisable recovery cause gbic-invalid errdisable recovery cause loopback errdisable recovery interval 30 #网络管理
版权声明:本文内容由网络用户投稿,版权归原作者所有,本站不拥有其著作权,亦不承担相应法律责任。如果您发现本站中有涉嫌抄袭或描述失实的内容,请联系我们jiasou666@gmail.com 处理,核实后本网站将在24小时内删除侵权内容。
发表评论
暂时没有评论,来抢沙发吧~