华为8000E防火培清理光模板拔出告警

网友投稿 277 2022-09-12


华为8000E防火培清理光模板拔出告警

HRP_Mdis alarm all2020-04-01 10:02:55.240

Index Level Date Time Info

1 Emergency 20-02-29 14:10:35 The optical module was removed.[GigabitEthernet1/0/6][OID:1.3.6.1.4.1.2011.5.25.219.2.4.1,EntCode:135680]

HRP_Mclear alarm index 1 no-trap Warning:Confirm to delete. continue?[Y/N]:yInfo: Succeed in deleting the current alarm!Apr 1 2020 10:04:17 HLHB-JB3F-C12-FW05-E8000 %%01SRM/3/RCDCMDACK(l)[0]:When deciding whether to excute command "clear alarm index 1 no-trap ", the user choose "Yes".

说明:

一、# 显示当前所有的告警信息。 display alarm all

Index Level Date Time Info

1 Emergency 15-03-05 11:25:40 The 48 V power supply for the board wa s abnormal.[LPU 5] 2 Emergency 15-03-05 11:25:38 The voltage of the board was lower tha n the lower fatal threshold.[SPU slot 6]

二、告警前面有个index索引号

三、clear alarm index 1 no-trapWarning:Confirm to delete. continue?[Y/N]:yInfo: Succeed in deleting the current alarm! 就是删除索引号为1的告警,并且不上报


版权声明:本文内容由网络用户投稿,版权归原作者所有,本站不拥有其著作权,亦不承担相应法律责任。如果您发现本站中有涉嫌抄袭或描述失实的内容,请联系我们jiasou666@gmail.com 处理,核实后本网站将在24小时内删除侵权内容。

上一篇:如何利用软件定义简化网络运营维护工作(网络运营和维护)
下一篇:时间同步综合测量解决方案(时间同步精度测试)
相关文章

 发表评论

暂时没有评论,来抢沙发吧~